50 changes: 47 additions & 3 deletions docs/vm/create-windows-vm.md
Original file line number Diff line number Diff line change
Expand Up @@ -68,7 +68,7 @@ The `bootOrder` values need to be set with the installation image first. If you
2. `Type`: Select `disk`.
3. `StorageClass`: You can use the default StorageClass `harvester-longhorn` or specify a custom one.
4. `Size`: The value `32` is set by default. See the disk space requirements for [Windows Server](https://docs.microsoft.com/en-us/windows-server/get-started/hardware-requirements#storage-controller-and-disk-space-requirements) and [Windows 11](https://docs.microsoft.com/en-us/windows/whats-new/windows-11-requirements#hardware-requirements) before changing this value.
5. `Bus`: The value `VirtIO` is set by default. You can keep it or change it to the other available options, `SATA` or `SCSI`.
5. `Bus`: The value `VirtIO` is set by default. For Windows workloads that generate sustained writes (for example large file copies, database write-ahead logs, or backup targets), `SCSI` (virtio-scsi) generally performs better than `VirtIO` (virtio-blk) — it supports multiple queues and has a more efficient DISCARD path. `SATA` is a compatible fallback for scenarios that cannot load paravirtualized drivers at boot time.
Comment thread
abonillabeeche marked this conversation as resolved.
Outdated
3. The **third volume** is a `Container` with the following values:
1. `Name`: The value `virtio-container-disk` is set by default. You can keep it or change it.
2. `Type`: Select `cd-rom`.
Expand All @@ -82,7 +82,7 @@ The `bootOrder` values need to be set with the installation image first. If you

1. The **Management Network** is added by default with the following values:
1. `Name`: The value `default` is set by default. You can keep it or change it.
2. `Model`: The value `e1000` is set by default. You can keep it or change it to the other available options from the dropdown.
2. `Model`: The value `e1000` is set by default so the guest can obtain network connectivity before paravirtualized drivers are installed. Once VMDP (or virtio-win drivers) is loaded inside the guest, switching to `virtio` provides higher throughput and lower CPU overhead for sustained network transfers.
Comment thread
abonillabeeche marked this conversation as resolved.
Outdated
3. `Network`: The value `management Network` is set by default. You can't change this option if no other network has been created. See [Harvester Network](../networking/harvester-network.md) for the full description on how to create new networks.
4. `Type`: The value `masquerade` is set by default. You can keep it or change it to the other available option, `bridge`.
2. You can add additional networks by clicking `Add Network`.
Expand All @@ -106,7 +106,7 @@ Changing the `Node Scheduling` settings can impact Harvester features, such as d
1. `OS Type`: The value `Windows` is set by default. It's recommended you don't change it.
2. `Machine Type`: The value `None` is set by default. It's recommended you don't change it. See the [KubeVirt Machine Type](https://kubevirt.io/user-guide/virtual_machines/virtual_hardware/#machine-type) documentation before you change this value.
3. (Optional) `Hostname`: Set the VM hostname.
4. (Optional) `Cloud Config`: Both `User Data` and `Network Data` values are set with default values. Currently, these configurations are not applied to Windows-based VMs.
4. (Optional) `Cloud Config`: Both `User Data` and `Network Data` values are set with default values. If the selected Windows image ships with [Cloudbase-Init](https://cloudbase.it/cloudbase-init/) (a common addition to modern Windows images), the `User Data` is processed at first boot and can inject per-VM configuration — SSH keys, local administrator accounts, VMDP install commands, hostname, first-boot PowerShell scripts, and so on. If the image does not include Cloudbase-Init, the `User Data` is still stored on the noCloud drive but nothing inside the guest will consume it.
Comment thread
abonillabeeche marked this conversation as resolved.
Outdated
5. (Optional) `Enable TPM`, `Booting in EFI mode`, `Secure Boot`: Both the TPM 2.0 device and UEFI firmware with Secure Boot are hard requirements for Windows 11.

:::note
Expand Down Expand Up @@ -173,6 +173,50 @@ For full instructions on how to install the VMDP guest driver and tools see the

:::

## Recommended Tuning

### Enable Hyper-V Enlightenments

Windows guests benefit substantially from KubeVirt's Hyper-V TLFS (Top-Level Functional Specification) enlightenment set — paravirtualized interrupt delivery (SynIC), the Hyper-V synthetic timer with direct interrupts, TLB flush hypercalls, VAPIC, and the Hyper-V clock timer. Enabling them typically:

- Reduces first-touch write allocation time on thin-provisioned storage.
- Smooths out sustained-write throughput and reduces periodic stalls during large file copies.
- Lowers per-interrupt scheduling overhead inside the guest.
Comment thread
abonillabeeche marked this conversation as resolved.
Outdated

The enlightenments are not enabled by default in the VM creation form. To apply them, click **Edit as YAML** in the VM edit view and add the following to `.spec.template.spec.domain`:

```yaml
features:
acpi: { enabled: true }
apic: { enabled: true }
smm: { enabled: true }
hyperv:
relaxed: { enabled: true }
vapic: { enabled: true }
spinlocks: { enabled: true, spinlocks: 8191 }
vpindex: { enabled: true }
synic: { enabled: true }
synictimer: { enabled: true }
ipi: { enabled: true }
runtime: { enabled: true }
reset: { enabled: true }
clock:
utc: {}
timer:
hpet: { present: false }
hyperv: { present: true }
pit: { tickPolicy: delay }
rtc: { tickPolicy: catchup }
```
Comment thread
abonillabeeche marked this conversation as resolved.
Outdated

Restart the VM for the changes to take effect. Verify from outside the guest:

```
kubectl get vmi <vm-name> -o json | jq '.spec.domain.features.hyperv'
```
Comment thread
abonillabeeche marked this conversation as resolved.
Outdated

The set above matches the "balanced set for performance and stability" recommended in the SUSE Support KB article [_Lower disk I/O performance in Windows 11 VMs compared to Linux guests on Harvester_](https://support.scc.suse.com/s/kb/Lower-disk-I-O-performance-in-Windows-11-VMs-compared-to-Linux-guests-on-Harvester). More aggressive enlightenments (`tlbflush`, `frequencies`, `reenlightenment`, or `synictimer` with `direct: true`) can be enabled per-VM when the cluster hardware supports them, but they may affect live-migration compatibility across nodes with different CPU generations — see the [KubeVirt Hyper-V enlightenments documentation](https://kubevirt.io/user-guide/compute/hyperv/) and the [SUSE Virtualization blog on tuning Windows VM performance](https://www.suse.com/c/tuning-windows-vm-performance-on-suse-virtualization/) for details.
Comment thread
abonillabeeche marked this conversation as resolved.
Outdated

## Known Issues

### Windows ISO unable to boot when using EFI mode
Expand Down
50 changes: 47 additions & 3 deletions versioned_docs/version-v1.8/vm/create-windows-vm.md
Original file line number Diff line number Diff line change
Expand Up @@ -68,7 +68,7 @@ The `bootOrder` values need to be set with the installation image first. If you
2. `Type`: Select `disk`.
3. `StorageClass`: You can use the default StorageClass `harvester-longhorn` or specify a custom one.
4. `Size`: The value `32` is set by default. See the disk space requirements for [Windows Server](https://docs.microsoft.com/en-us/windows-server/get-started/hardware-requirements#storage-controller-and-disk-space-requirements) and [Windows 11](https://docs.microsoft.com/en-us/windows/whats-new/windows-11-requirements#hardware-requirements) before changing this value.
5. `Bus`: The value `VirtIO` is set by default. You can keep it or change it to the other available options, `SATA` or `SCSI`.
5. `Bus`: The value `VirtIO` is set by default. For Windows workloads that generate sustained writes (for example large file copies, database write-ahead logs, or backup targets), `SCSI` (virtio-scsi) generally performs better than `VirtIO` (virtio-blk) — it supports multiple queues and has a more efficient DISCARD path. `SATA` is a compatible fallback for scenarios that cannot load paravirtualized drivers at boot time.
3. The **third volume** is a `Container` with the following values:
1. `Name`: The value `virtio-container-disk` is set by default. You can keep it or change it.
2. `Type`: Select `cd-rom`.
Expand All @@ -82,7 +82,7 @@ The `bootOrder` values need to be set with the installation image first. If you

1. The **Management Network** is added by default with the following values:
1. `Name`: The value `default` is set by default. You can keep it or change it.
2. `Model`: The value `e1000` is set by default. You can keep it or change it to the other available options from the dropdown.
2. `Model`: The value `e1000` is set by default so the guest can obtain network connectivity before paravirtualized drivers are installed. Once VMDP (or virtio-win drivers) is loaded inside the guest, switching to `virtio` provides higher throughput and lower CPU overhead for sustained network transfers.
3. `Network`: The value `management Network` is set by default. You can't change this option if no other network has been created. See [Harvester Network](../networking/harvester-network.md) for the full description on how to create new networks.
4. `Type`: The value `masquerade` is set by default. You can keep it or change it to the other available option, `bridge`.
2. You can add additional networks by clicking `Add Network`.
Expand All @@ -106,7 +106,7 @@ Changing the `Node Scheduling` settings can impact Harvester features, such as d
1. `OS Type`: The value `Windows` is set by default. It's recommended you don't change it.
2. `Machine Type`: The value `None` is set by default. It's recommended you don't change it. See the [KubeVirt Machine Type](https://kubevirt.io/user-guide/virtual_machines/virtual_hardware/#machine-type) documentation before you change this value.
3. (Optional) `Hostname`: Set the VM hostname.
4. (Optional) `Cloud Config`: Both `User Data` and `Network Data` values are set with default values. Currently, these configurations are not applied to Windows-based VMs.
4. (Optional) `Cloud Config`: Both `User Data` and `Network Data` values are set with default values. If the selected Windows image ships with [Cloudbase-Init](https://cloudbase.it/cloudbase-init/) (a common addition to modern Windows images), the `User Data` is processed at first boot and can inject per-VM configuration — SSH keys, local administrator accounts, VMDP install commands, hostname, first-boot PowerShell scripts, and so on. If the image does not include Cloudbase-Init, the `User Data` is still stored on the noCloud drive but nothing inside the guest will consume it.
5. (Optional) `Enable TPM`, `Booting in EFI mode`, `Secure Boot`: Both the TPM 2.0 device and UEFI firmware with Secure Boot are hard requirements for Windows 11.

:::note
Expand Down Expand Up @@ -173,6 +173,50 @@ For full instructions on how to install the VMDP guest driver and tools see the

:::

## Recommended Tuning

### Enable Hyper-V Enlightenments

Windows guests benefit substantially from KubeVirt's Hyper-V TLFS (Top-Level Functional Specification) enlightenment set — paravirtualized interrupt delivery (SynIC), the Hyper-V synthetic timer with direct interrupts, TLB flush hypercalls, VAPIC, and the Hyper-V clock timer. Enabling them typically:

- Reduces first-touch write allocation time on thin-provisioned storage.
- Smooths out sustained-write throughput and reduces periodic stalls during large file copies.
- Lowers per-interrupt scheduling overhead inside the guest.

The enlightenments are not enabled by default in the VM creation form. To apply them, click **Edit as YAML** in the VM edit view and add the following to `.spec.template.spec.domain`:

```yaml
features:
acpi: { enabled: true }
apic: { enabled: true }
smm: { enabled: true }
hyperv:
relaxed: { enabled: true }
vapic: { enabled: true }
spinlocks: { enabled: true, spinlocks: 8191 }
vpindex: { enabled: true }
synic: { enabled: true }
synictimer: { enabled: true }
ipi: { enabled: true }
runtime: { enabled: true }
reset: { enabled: true }
clock:
utc: {}
timer:
hpet: { present: false }
hyperv: { present: true }
pit: { tickPolicy: delay }
rtc: { tickPolicy: catchup }
```

Restart the VM for the changes to take effect. Verify from outside the guest:

```
kubectl get vmi <vm-name> -o json | jq '.spec.domain.features.hyperv'
```

The set above matches the "balanced set for performance and stability" recommended in the SUSE Support KB article [_Lower disk I/O performance in Windows 11 VMs compared to Linux guests on Harvester_](https://support.scc.suse.com/s/kb/Lower-disk-I-O-performance-in-Windows-11-VMs-compared-to-Linux-guests-on-Harvester). More aggressive enlightenments (`tlbflush`, `frequencies`, `reenlightenment`, or `synictimer` with `direct: true`) can be enabled per-VM when the cluster hardware supports them, but they may affect live-migration compatibility across nodes with different CPU generations — see the [KubeVirt Hyper-V enlightenments documentation](https://kubevirt.io/user-guide/compute/hyperv/) and the [SUSE Virtualization blog on tuning Windows VM performance](https://www.suse.com/c/tuning-windows-vm-performance-on-suse-virtualization/) for details.

## Known Issues

### Windows ISO unable to boot when using EFI mode
Expand Down