FreeRtos stopss logger Stream #1245

Description

@brinzebuah

Board: Nucleo F439ZI
I have a class which prints strings via the modm logger. As soon as i add a Mutex as an Class-Attribut I receive with hTerm only the first letter of the String, even if i not use the Mutex at all. If I initilazie the Mutex with an nullPtr I receive the whole string.
Why is this happening?
I'm a FreeRtos Noob, so i'm happy for every input.

Class "testMutex.cpp" :

#include <modm/board.hpp>
#include <modm/processing.hpp>

class TestMutex
{
public:
    TestMutex() = default;

    void
    hello()
    {
        modm::log::debug << "Welcome to Debug Stream example modm" << modm::endl;
    }

private:
    modm::rtos::Mutex mMutex;
    int mValue;
};

main:

#include "testMutex.cpp"
#include <modm/board.hpp>

#undef MODM_LOG_LEVEL
#define MODM_LOG_LEVEL modm::log::DEBUG

int
main()
{
    Board::initialize();
    TestMutex helloMutex;
    helloMutex.hello();
}